TESTERS & MONITORS
ULTRAMETER™ III 9PTKB

ULTRAMETER™ III 9PTKB
ULTRAMETER III 9P™ | Hard Carry Case Kit |
Display: 4 Digit LCD | Outer Material: ABS plastic |
Dimensions (LxWxH): 196 x 68 x 64 mm/7.7 x 2.7 x 2.5 in. | Inner Material: Foam |
Weight: 352 g/12.4 oz. | Dimensions: L x W x D: 13.6 x 10 x 5.4 in./346 x 254 x 137 mm |
Case/Cell Material: VALOX®* | * ® Sabic Innovative Plastics IP BV |
Cell Capacities (w/o cell extender): pH/ORP 1,2 mL/0.04 oz.
Cond/TDS/Res: 5 mL/0.2 oz. |
|
Power: 9v Alkaline Battery | |
Battery Life: 100 Hours/5000 Readings | |
Operating/Storage Temperature: 0-55°C/32-132°F | |
Protection Ratings: IP67/NEMA 6 (waterproof to 1 meter/3 feet) | |
EMI/EMC Ratings (Conformité Européenne): IEC 61326-1: 2020; CISPR 11: 2015 +A1: 2016 +A2: 2019; IEC 61000-4-2: 2008; IEC 61000-4-3: 2010; IEC 61000-4-8: 2009; (EU) 2015/863 (RoHS3): +(EU) 2024/232 |
Functional Specifications:
Conductivity | Ranges: 0–9999 μS/cm; 10–200 mS/cm; in 5 autoranges |
Resolution: 0.01(<100 μS); 0.1(<1000 μS); 1(<10 mS); 0.01(<100 mS); 0.1(<200 mS) | |
Accuracy: ±1% of reading | |
Auto Temperature Compensation: 0–71°C / 32–160°F | |
Adjustable Temperature Compensation to 25°C: 0–9.99%/°C | |
Conductivity/TDS Ratios Preprogrammed: KCl, 442*, NaCl | |
Adjustable Conductivity/TDS Ratio Factor: 0.20–7.99 | |
TDS | Ranges: 0–9999 ppm; 10–200 ppt; in 5 autoranges |
Resolution: 0.01(<100 ppm); 0.1(<1000 ppm); 1(<10 ppt); 0.01(<100 ppt); 0.1(<200 ppt) | |
Accuracy: ±1% of reading | |
Auto Temperature Compensation: 0–71°C / 32–160°F | |
Adjustable Temperature Compensation to 25°C: 0–9.99%/°C | |
Conductivity/TDS Ratios Preprogrammed: KCl, 442*, NaCl | |
Adjustable Conductivity/TDS Ratio Factor: 0.20–7.99 | |
Resistivity | Ranges: 10 KΩ–30 MΩ |
Resolution: 0.01(<100 KΩ); 0.1(<1000 KΩ); 0.1(>1 MΩ) | |
Accuracy: ±1% of reading | |
Auto Temperature Compensation: 0–71°C / 32–160°F | |
Adjustable Temperature Compensation to 25°C: 0–9.99%/°C | |
pH | Ranges: 0–14 pH |
Resolution: 0.01 pH | |
Accuracy**: ±0.01 pH | |
Auto Temperature Compensation: 0–71°C / 32–160°F | |
ORP | Ranges: ±999 mV |
Resolution: 1 mV | |
Accuracy**: ±1 mV | |
Free Chlorine FCE™ | Ranges: 0.00–9.99 ppm when 350≤ORPmV<725 and 0.0≤pH<9.9 and when 725≤ORPmV<825 and 0.0≤pH<8.9 |
Resolution: 0.01 ppm | |
Accuracy**: <1.00ppm ±0.3ppm and ≥1.00ppm ±0.2ppm | |
Auto Temperature Compensation: 0–71°C / 32–160°F | |
Alkalinity Titration | Ranges: 10-800 ppm |
Resolution: 0.1 ppm | |
Hardness Titration | Ranges: 0-1710 ppm / 0-100 grains |
Resolution: 0.1(<1000 ppm); 1(<1710 ppm); 0.1(<100 grains) | |
LSI Calculator | Ranges: -10 to +10 |
Resolution: 0.01 | |
Temperature | Ranges: 0–71°C / 32–160°F |
Resolution: 0.1°C/F | |
Accuracy: ±0.1°C |
*442 Natural Water Standard™ Myron L® Company
**EM Susceptibility: When measuring 4.00 pH Buffer in 3.5 molar KCl:
± 0.2 pH in the presence or RF fields ≥ 3 V/m.
± 0.37 pH in the presence of RF fields ≥ 3 V/m at 300 MHz (± 30 MHz) and 625 MHz (± 50 MHz ).
Data Sheet