TESTERS & MONITORS
POOLPRO™ PS6FCᴱ & PS9TKB

POOLPRO™ PS6FCᴱ & PS9TKB
POOLPRO™ Specifications:
Display: 4 Digit Liquid Crystal Display |
Dimensions: LxWxH 196 x 68 x 64 mm/ 7.7 x 2.7 x 2.5 in. |
Weight: 352 g/12.4 oz. |
Case/conductivity cell material: VALOX™ |
Cell capacities (w/o cell extender): pH/ORP: 1,2 mL/0.04 oz. Cond/TDS/MIN/SALT: 5 mL/0.2 oz. |
Power: 9V alkaline battery |
Battery life: >100 hours (5000 readings) |
Operating/storage temperature: 0 – 55°C/32 – 132°F |
Protection Ratings: IP67/NEMA 6 (waterproof to 1 meter/3 feet) |
EMI/EMC Ratings (Conformité Européenne): IEC 61326-1: 2020; CISPR 11: 2015 +A1: 2016 +A2: 2019; IEC 61000-4-2: 2008; IEC 61000-4-3: 2010; IEC 61000-4-8: 2009; (EU) 2015/863 (RoHS3): +(EU) 2024/232 |
*™SABIC INNOVATIVE PLASTICS IP BV
Functional Specifications:
Conductivity | Ranges: 0–9999 μS/cm; 10–200 mS/cm; in 5 autoranges |
Resolution: 0.01(<100 μS); 0.1(<1000 μS); 1(<10 mS); 0.01(<100 mS); 0.1(<200 mS) | |
Accuracy: ±1% of reading | |
Auto Temperature Compensation: 0–71°C / 32–160°F | |
Conductivity/TDS Ratios Preprogrammed: KCl, 442*, NaCl | |
TDS | Ranges: 0–9999 ppm; 10–200 ppt; in 5 autoranges |
Resolution: 0.01(<100 ppm); 0.1(<1000 ppm); 1(<10 ppt); 0.01(<100 ppt); 0.1(<200 ppt) | |
Accuracy: ±1% of reading | |
Auto Temperature Compensation: 0–71°C / 32–160°F | |
Conductivity/TDS Ratios Preprogrammed: KCl, 442*, NaCl | |
Mineral/Salt | Ranges: 0–200 ppt; in 5 autoranges |
Resolution: 0.01(<100 ppm); 0.1(<1000 ppm); 1(<10 ppt); 0.01(<100 ppt); 0.1(<200 ppt) | |
Accuracy: ±1% of reading | |
Auto Temperature Compensation: 0–71°C / 32–160°F | |
Conductivity/TDS Ratios Preprogrammed: KCl, 442*, NaCl | |
pH | Ranges: 0–14 pH |
Resolution: 0.01 pH | |
Accuracy**: ±0.01 pH | |
Auto Temperature Compensation: 0–71°C / 32–160°F | |
ORP | Ranges: ±999 mV |
Resolution: 1 mV | |
Accuracy**: ±1 mV | |
Free Chlorine FCE™ | Ranges: 0.00–9.99 ppm when 350≤ORPmV<725 and 0.0≤pH<9.9 and when 725≤ORPmV<825 and 0.0≤pH<8.9 |
Resolution: 0.01 ppm | |
Accuracy**: <1.00ppm ±0.3ppm and ≥1.00ppm ±0.2ppm | |
Auto Temperature Compensation: 0–71°C / 32–160°F | |
Alkalinity Titration | Ranges: 10-800 ppm |
Resolution: 0.1 ppm | |
Hardness Titration | Ranges: 0-1710 ppm / 0-100 grains |
Resolution: 0.1(<1000 ppm); 1(<1710 ppm); 0.1(<100 grains) | |
LSI Calculator | Ranges: -10 to +10 |
Resolution: 0.01 | |
Temperature | Ranges: 0–71°C / 32–160°F |
Resolution: 0.1°C/F | |
Accuracy: ±0.1°C |
*442 Natural Water Standard™ Myron L® Company
**EM Susceptibility: When measuring 4.00 pH Buffer in 3.5 molar KCl:
± 0.2 pH in the presence or RF fields ≥ 3 V/m.
± 0.37 pH in the presence of RF fields ≥ 3 V/m at 300 MHz (± 30 MHz) and 625 MHz (± 50 MHz ).
Data Sheet